top of page

IPPIC Pre-eclampsia

Validation and development of models using clinical, biochemical and ultrasound markers for predicting pre-eclampsia: an individual participant data meta-analysis

doi: 10.3310/hta24720

BACKGROUND

Pre-eclampsia is a leading cause of maternal and perinatal mortality and morbidity. Early identification of women at risk is needed to plan management.

OBJECTIVES

To assess the performance of existing pre-eclampsia prediction models and to develop and validate models for pre-eclampsia using individual participant data meta-analysis. We also estimated the prognostic value of individual markers.

DESIGN

This was an individual participant data meta-analysis of cohort studies.

SETTING

Source data from secondary and tertiary care.

PREDICTORS

We identified predictors from systematic reviews, and prioritised for importance in an international survey.

PRIMARY OUTCOMES

Early-onset (delivery at < 34 weeks' gestation), late-onset (delivery at ≥ 34 weeks' gestation) and any-onset pre-eclampsia.

ANALYSIS

We externally validated existing prediction models in UK cohorts and reported their performance in terms of discrimination and calibration. We developed and validated 12 new models based on clinical characteristics, clinical characteristics and biochemical markers, and clinical characteristics and ultrasound markers in the first and second trimesters. We summarised the data set-specific performance of each model using a random-effects meta-analysis. Discrimination was considered promising for C-statistics of ≥ 0.7, and calibration was considered good if the slope was near 1 and calibration-in-the-large was near 0. Heterogeneity was quantified using I2 and τ2. A decision curve analysis was undertaken to determine the clinical utility (net benefit) of the models. We reported the unadjusted prognostic value of individual predictors for pre-eclampsia as odds ratios with 95% confidence and prediction intervals.

RESULTS

The International Prediction of Pregnancy Complications network comprised 78 studies (3,570,993 singleton pregnancies) identified from systematic reviews of tests to predict pre-eclampsia. Twenty-four of the 131 published prediction models could be validated in 11 UK cohorts. Summary C-statistics were between 0.6 and 0.7 for most models, and calibration was generally poor owing to large between-study heterogeneity, suggesting model overfitting. The clinical utility of the models varied between showing net harm to showing minimal or no net benefit. The average discrimination for IPPIC models ranged between 0.68 and 0.83. This was highest for the second-trimester clinical characteristics and biochemical markers model to predict early-onset pre-eclampsia, and lowest for the first-trimester clinical characteristics models to predict any pre-eclampsia. Calibration performance was heterogeneous across studies. Net benefit was observed for International Prediction of Pregnancy Complications first and second-trimester clinical characteristics and clinical characteristics and biochemical markers models predicting any pre-eclampsia, when validated in singleton nulliparous women managed in the UK NHS. History of hypertension, parity, smoking, mode of conception, placental growth factor and uterine artery pulsatility index had the strongest unadjusted associations with pre-eclampsia.

LIMITATIONS

Variations in study population characteristics, type of predictors reported, too few events in some validation cohorts and the type of measurements contributed to heterogeneity in performance of the International Prediction of Pregnancy Complications models. Some published models were not validated because model predictors were unavailable in the individual participant data.

CONCLUSION

For models that could be validated, predictive performance was generally poor across data sets. Although the International Prediction of Pregnancy Complications models show good predictive performance on average, and in the singleton nulliparous population, heterogeneity in calibration performance is likely across settings.

FUTURE WORK

Recalibration of model parameters within populations may improve calibration performance. Additional strong predictors need to be identified to improve model performance and consistency. Validation, including examination of calibration heterogeneity, is required for the models we could not validate.

External validation of prognostic models predicting pre-eclampsia: individual participant data meta-analysis

doi:10.1186/s12916-020-01766-9

BACKGROUND
Pre-eclampsia is a leading cause of maternal and perinatal mortality and morbidity. Early identification of women at risk during pregnancy is required to plan management. Although there are many published prediction models for pre-eclampsia, few have been validated in external data. Our objective was to externally validate published prediction models for pre-eclampsia using individual participant data (IPD) from UK studies, to evaluate whether any of the models can accurately predict the condition when used within the UK healthcare setting.
 
METHODS
IPD from 11 UK cohort studies (217,415 pregnant women) within the International Prediction of Pregnancy Complications (IPPIC) pre-eclampsia network contributed to external validation of published prediction models, identified by systematic review. Cohorts that measured all predictor variables in at least one of the identified models and reported pre-eclampsia as an outcome were included for validation. We reported the model predictive performance as discrimination (C-statistic), calibration (calibration plots, calibration slope, calibration-in-the-large), and net benefit. Performance measures were estimated separately in each available study and then, where possible, combined across studies in a random-effects meta-analysis.

RESULTS
Of 131 published models, 67 provided the full model equation and 24 could be validated in 11 UK cohorts. Most of the models showed modest discrimination with summary C-statistics between 0.6 and 0.7. The calibration of the predicted compared to observed risk was generally poor for most models with observed calibration slopes less than 1, indicating that predictions were generally too extreme, although confidence intervals were wide. There was large between-study heterogeneity in each model’s calibration-in-the-large, suggesting poor calibration of the predicted overall risk across populations. In a subset of models, the net benefit of using the models to inform clinical decisions appeared small and limited to probability thresholds between 5 and 7%.

CONCLUSIONS
The evaluated models had modest predictive performance, with key limitations such as poor calibration (likely due to overfitting in the original development datasets), substantial heterogeneity, and small net benefit across settings. The evidence to support the use of these prediction models for pre-eclampsia in clinical decision-making is limited. Any models that we could not validate should be examined in terms of their predictive performance, net benefit, and heterogeneity across multiple UK settings before consideration for use in practice.

  • Facebook
  • Twitter
  • LinkedIn

**Important: The content on this website is currently only for educational and research purposes**

©2018 BY INTERNATIONAL PREDICTION OF PREGNANCY COMPLICATIONS (IPPIC). PROUDLY CREATED WITH WIX.COM

bottom of page